Appendix E ProView 7000™ Alarm List
Short Description
Input failure
Link down
Low delay stream while
configured to normal
mode
Multiplex Backup Port
Activated
MPEG Sync Loss on
Backup Port
MPEG Sync Loss on
Primary Port
MPEG TS Input Overflow
MPEG TS Output
Overflow
No Genlock Sync
No PCR detected
Normal stream while
configured to low delay
Packet Loss Detected
After CAM
PER Too High
PID conflict
PID Missing on Backup
Port
PID Missing on Primary
Port
© 2012 Harmonic Inc.
Severity
Both source inputs failed.
Critical
Verify that the cables are properly connected on both ends
Verify the reception conditions
Consider adjusting the redundancy mode or triggers
Link down has been detected on the GbE port.
Major
Check:
That the cable is properly connected on both ends.
That the ports on both ends are enabled.
Low delay stream received while decoder buffer management
Warning
mode configured to normal mode. Configure the decoder buffer
management mode to low delay.
The backup multiplex port has been activated. It is
Warning
recommended to revert to the primary port as soon as possible.
The device cannot sync to the input stream.
Warning
Verify that the input contains a valid MPEG transport stream.
The device cannot sync to the input stream.
Major
Verify that the input contains a valid MPEG transport stream.
The input bitrate is too high.
Major
Contact Harmonic's help desk.
The Output bitrate is too high.
Major
Reduce the bitrate or contact Harmonic's help desk.
The program cannot be decoded properly since the decoder
Major
could not sync to input Genlock signal.
Verify that the Genlock input is properly wired and that the
decoder display is configured correctly.
This may cause AV sync issues.
Warning
Check the PCR PID configuration.
Configure the decoder buffer management mode to Normal
Warning
Delay.
Packets were dropped by the CAM.
Major
Verify:
The input bitrate does not exceed the CAM limit
The CAM supports the number of descrambled programs.
If the problem persists please contact your CAM vendor.
Verify reception conditions and wiring.
Warning
More than one PID is mapped to the same output PID. Check
Major
the output configuration.
No bitrate detected on this PID. Problem originating up stream.
Warning
No bitrate detected on this PID. Problem originating up stream.
Major
197
Corrective Action
ProView 7000 v.2.6, Rev. E