Chapter 7 Device Configuring Using EMS
The Multiplex In Port dialog comprises:
General box
■
Enabled – Use to enable or disable the multiplex input.
❑
Transport Stream ID – Displays the transport stream's ID.
❑
Table Extraction – Use to select PSI/SI for DVB or PSI for MPEG. For ATSC systems, set the
❑
stream type to MPEG. The default is PSI/SI.
Assigned CAMs – Displays CAM slots assigned to the multiplex input.
❑
Primary Source Port – Use to select the primary physical input port for the multiplex
❑
input.
Input Redundancy box
■
Redundancy Mode
❑
Backup Source Port
❑
Active Port
❑
Redundancy Triggers
❑
• MPEG Sync Loss Alarm tab
· Trigger Alarm – use to enable or disable the trigger, default is Enable.
· Primary Port Event Duration – set the period that the state must exist to trigger
redundancy
· Backup Port Event Duration – set the period that the state must exist to trigger
redundancy
• CC Errors Alarm tab
· Trigger Alarm – use to enable or disable the trigger, default is Enable.
· Primary Port Number of Errors – set the number of CC errors that must occur within
a period to trigger redundancy
· Primary Port Within – set the period that the number of CC errors must occur
within to trigger redundancy
· Backup Port Number of Errors – set the number of CC errors that must occur within
a period to trigger redundancy
· Backup Port Within – set the period that the number of CC errors must occur within
to trigger redundancy
• PID Missing Alarm tab
· Trigger Alarm – use to enable or disable the trigger, default is Enable.
· PID – set the PID number
· Primary Port Missing For – set the period that the PID must be missing for to trigger
redundancy
· Backup Port Missing For– set the period that the PID must be missing for to trigger
redundancy
© 2012 Harmonic Inc.
93
Multiplex Inputs
ProView 7000 v.2.6, Rev. E
Need help?
Do you have a question about the ProView 7000 and is the answer not in the manual?