Step 8: Connect To Power - Christie Solaria CP2210 Setup Manual

Solaria series
Hide thumbs Also See for Solaria CP2210:
Table of Contents

Advertisement

Section 2: Installation and Setup

2.3.7 Step 8: Connect to Power

WARNING
• DO NOT attempt operation if the AC supply and cord are
not within the specified voltage and power range. Refer
to Section 6 - Specifications from the CP2210 User Man-
ual (020-100410-xx).
• Always power down the projector before unplugging the
AC line cord. The appropriate ratings for the projector are
listed on the licence label (located on the back of the pro-
jector). Wait 15 minutes for the main exhaust fan to turn
OFF and for the lamp to cool sufficiently before unplug-
ging the projector.
• Ground (earth) connection is necessary for safety. Never
compromise safety by returning the current through the
ground. Connect ground FIRST to reduce shock hazard
from high leakage.
NOTICE! Use the line cord provided with each projector. DO NOT compromise safety by
using other connectors. For all other regions, ensure a line cord, power plug and socket that
meet the appropriate rating standards are used. For more information, refer to 3.1.1
Powering Up the Projector, on page 3-1.
This is a manual power-up
procedure. Some installations may
include an automation system that
controls lamp ignition in conjunction
with other theater variables, such as
house lights, audio and the start of
the feature from a digital media
storage device/server.
is powered by 200-240VAC power
from the theater. The switching
Lamp Power Supply (LPS) provides
a well regulated DC current up to 85
amps with a maximum LPS power of
2.1kW. The power output from the
LPS is controlled by the PIB, via a
dedicated 'RS232' connection from
the Backplane to the LPS. A switch
selectable secondary 100-240VAC inlet is provided, allowing the main electronics to be powered separately,
via a universal 100-240VAC UPS. The main LPS is powered through the main 200-240VAC inlet. A discrete
AC switch above the 2 inlets (
from the main inlet (requiring only 1 power cord to supply the entire unit), or the secondary inlet supplied by
the UPS, via an additional line cord (not provided).
1. Connect the projector's line cord to the AC receptacle at the lower-left rear corner of the projector and to
proper AC - the outlets must be near the equipment and easily accessible. Use only the line cord provided
with the projector or a power cord of appropriate ratings that comply with regional standards. When the
main inlet is used the AC switch must be set to the left (Figure 2-10).
2-8
=
T he projector
) allows the user to select whether the main electronics are powered
Figure 2-9
Figure 2-9
Figure 2-10 Connecting to Power
AC Receptacle
CP2210 Setup Guide
020-100524-02 Rev. 1 (11-2010)