Connect To Ac Power - Christie D4K2560 User Manual

Hide thumbs Also See for D4K2560:
Table of Contents

Advertisement

Connect to AC Power

Failure to comply with the following could result in death or serious injury:
• Certified electrician required during installation. Ground (earth) connection is necessary
• Use an appropriate strain relief connector on the AC supply cable to prevent the cable
When connecting the projector directly to AC power, follow all electrical codes for your
location. In addition, follow these recommendations:
• Use 10AWG or 8AWG wiring. The distance between the wall circuit breaker and the
• For North American installations, use at least 10AWG copper wires for the connection of
• Copper or aluminum are acceptable as conductor wiring material to the terminal block.
When connecting the projector to AC power with a pluggable type-B cable, follow all
electrical codes for your location. In addition, follow these recommendations:
• There must be easy access to the current protection device or breaker in the building.
• Use minimum 10AWG wiring, with a maximum length of 4.5 m for U.S and Canada. For
• The socket-outlet is installed near the equipment and is easily accessible.
• The plug can be used as the device disconnect and is near the unit and easily accessible.
1. On the bottom of the projector in the front lamp-side corner, loosen the 2 screws and slide the
access panel to expose the terminal block.
2. Remove 4 screws securing the knockout plate to the bottom right corner of the front bezel.
Remove the knockout plate. The AC supply is routed to the terminal block through an appropriate
strain relief mounted on this knockout plate.
D4K2560 User Manual
020-101076-01 Rev. 1 (06-2013)
for safety. Never compromise safety by returning the current through the ground.
Connect ground FIRST to reduce shock hazard.
from rubbing against the LPS knockout plate and becoming damaged.
projector must not exceed 20 meters using 10AWG cables or 30 meters using 8AWG
cables.
the main AC supply to the projector's ground lug.
international installations the length should be based on the local electrical codes.
The circuit breaker on the projector baseplate (located under the front lens-side corner)
can also be used as a means of disconnect.
1
2
Installation and Setup
11

Advertisement

Table of Contents
loading

Table of Contents