Connect Lamp Power Supply (Lps) - Christie D4K35 Setup Manual

Hide thumbs Also See for D4K35:
Table of Contents

Advertisement

Section 2: Installation and Setup
Table 2.2 Lamp Types Available for D4K35 and Anode Yoke Position
LAMP
2.0 kW and 3.0kW
4.5 and 6.0kW
7. Install the lamp. See

2.15 Connect Lamp Power Supply (LPS)

connected to the cathode lead and the red (+) power cable must be connected to the anode
lead. Reversing the connections can damage the projector.
WARNING
WARNING
safety. Never compromise safety by returning the current through the ground. 3) Connect
ground FIRST to reduce shock hazard.
WARNING
the cable from rubbing against the LPS knockout plate and becoming damaged
2-16
TYPE
CDXL-20
CDXL-30
CXL-20*
CXL-30
CDXL-45
CDXL-60
Section 6.9 Replace the Lamp
Figure 2-21 Anode Clamp Location
When connecting the LPS and the Igniter the black (-) power cable must be
You must connect the LPS to the projector before you connect it to AC power.
1) Certified electrician required. 2) Ground (earth) connection is necessary for
Use an appropriate strain relief connector on the AC supply cable to prevent
ANODE YOKE POSITION
Move the lamp cradle to the rear position, which is approximately
1" closer to the reflector.
*NOTE: A lamp adapter kit must be used with the CXL-20 lamp.
Move the lamp cradle as far forward as possible (position closest
to igniter)
for lamp replacement instructions.