Lens Mount Horizontal Boresight - Christie Solaria CP2210 Setup Manual

Solaria series
Hide thumbs Also See for Solaria CP2210:
Table of Contents

Advertisement

8. When the top and bottom of the image are equally in focus lock the set screw to hold that position.
Recheck the image.
9. If fine tuning is required, focus the image at the left and right sides. Refer to
Boresight, on page

Lens Mount Horizontal Boresight

optimal lens performance (i.e. factory setup of absolute lens distance to the prism). It is
critical that each turn of the cap screws is tracked to ensure adjustments are accurate.
Horizontal boresight should only be adjusted if a large horizontal tilt to the screen is required
1. When top/bottom boresight is complete, fine tune the image at the left and right sides of the screen.
2. Select an appropriate test pattern for boresight adjustments, via the TPC by clicking the Test Patterns
button
Administrator Setup: Preferred Test Pattern Setup window. It is recommended to use the DC2K
Framing test pattern.
3. Use a 5mm hex key to loosen the set screw for right boresight (/B).
4. Use the 5mm hex key to turn the right adjust cap screw (/A) 1/16 of a turn clockwise.
5. Adjust the left adjust cap screw equally in the opposite direction (
6. Check the screen. If the projected image is worse than before the adjustment was made turn the right adjust
cap screw 1/16 of turn counter-clockwise. Ensure the left adjuster is adjusted equally in the opposite
direction.
CP2210 Setup Guide
020-100524-02 Rev. 1 (11-2010)
2-15.
Only adjust vertical boresight 1/8 of a turn or less at one time to maintain
Figure 2-18 Left/Right Image Adjustment
from the Main panel. This will launch a collection of test patterns predefined in the
Section 2: Installation and Setup
Lens Mount Horizontal
A
Right Boresight Cap Screw
B
Right Boresight Set Screw
C
Left Boresight Cap Screw
D
Left Boresight Set Screw
).
/C
2-15

Advertisement

Table of Contents
loading

Table of Contents