Connect the lamp power supply

Danger! Failure to comply with the following results in death or serious injury.
In a multi-projector installation there is a risk of a Fire Hazard if the high current DC cables and
interlock/control cables are incorrectly cross-connected between the projector heads and lamp power
supplies (LPSs).
To avoid cross connections between projectors and lamp power supplies, always perform this
procedure in its entirety for each projector, one after another. Never attempt to connect multiple
projectors and lamp power supplies together at the same time.
Before powering the projector on for the first time, check that the high current DC leads and
interlock/control cables are correctly connected between the LPS and its corresponding projector.
Failure to comply may result in a Fire Hazard.
Warning! Failure to comply with the following could result in death or serious injury.
• Certified electrician required during installation. Ground (earth) connection is necessary for safety.
Never compromise safety by returning the current through the ground. Connect ground first to
reduce shock hazard.
• Use an appropriate strain relief connector on the AC supply cable to prevent the cable from rubbing
against the LPS knockout plate and becoming damaged.
6
5
4
1. Ensure the power is disconnected from the lamp power supply (LPS).
2. Loosen three screws to remove the rear lens-side cover.
3. Connect the LPS communication cables:
a. Connect one end of the RS232 cable to the lower port on the LPS labeled RS232.
b. Connect one end of the Interlock cable to the upper port on the LPS labeled Interlock.
D4K3560 Setup Guide