4.3 Power connection — New a Series
4
3
5
6
1. Multifunction display rear panel connections.
2. Power cable.
3. Connection to 12 V power supply
4. Red cable (positive).
5. Shield (drain) wire (thin black wire; must be connected to RF
ground point).
6. Black cable (negative).
Power distribution
Raymarine recommends that all power connections are made via a
distribution panel.
• All equipment must be powered from a breaker or switch, with
appropriate circuit protection.
• All equipment should be wired to individual breakers if possible.
Warning: Product grounding
Before applying power to this product, ensure it has
been correctly grounded, in accordance with the
instructions in this guide.
Grounding — Dedicated drain wire
The power cable supplied with this product includes a dedicated
shield (drain) wire for connection to a vessel's RF ground point.
It is important that an effective RF ground is connected to the
system. A single ground point should be used for all equipment.
The unit can be grounded by connecting the shield (drain) wire of
the power cable to the vessel's RF ground point. On vessels without
an RF ground system the shield (drain) wire should be connected
directly to the negative battery terminal.
The dc power system should be either:
• Negative grounded, with the negative battery terminal connected
to the vessel's ground.
• Floating, with neither battery terminal connected to the vessel's
ground
Warning: Positive ground systems
Do not connect this unit to a system which has positive
grounding.
Power cable
The display is supplied with a power cable, this can be extended
if required..
Power cables available
For flush mount installations a right angled power cable (not
supplied) is available.
Cable
Part number
Right angled power
A80021
cable
40
1
2
D12581-1
Notes
Cable extension
The following restrictions apply to any extension to the power cable:
• Cable must be of a suitable gauge for the circuit load.
• Each unit should have its own dedicated power cable wired back
to the distribution panel.
Total length (max)
Supply voltage
0–5 m (0–16.4 ft)
12 V
5–10 m (16.4–32.8 ft)
12 V
12 V
10–15 m (32.8–49.2 ft)
15–20 m (49.2–65.5 ft)
12 V
Note: These distances are for a 2 wire power cable run from the battery to
the display (approximately the distance from the battery to the display). To
calculate the round trip length, double the figure stated here.
Breakers, fuses and circuit protection
The unit includes an internal fuse. It is recommended that you fit an
additional thermal breaker or fuse at the distribution panel.
Thermal breaker rating
5 A (if only connecting one device)
Note: The suitable fuse rating for the thermal breaker is
dependent on the number of devices you are connecting. If in
doubt consult an authorized Raymarine dealer.
Cable gauge (AWG)
18
14
12
12
New a Series / New c Series / New e Series