9.4

Keypad and Area Programming

9.4.1

Keypad Area Programming

Keypad
no.
1
2
3
4
5
6
7
8
Value range: 00 = master keypad, 01 – 16 = are 01 – 16, 99 = not used
Notice!
The system supports up to 16 master keypads. When the master keypad is not switched to
the corresponding area, no arming/disarming, bypass and alarm reset operations can be
performed on the master keypad. Operations can only be performed in the area when the
master keypad is switched to the corresponding area.
9.4.2

Area Timing Programming

Exit and Entry Delay Time
Area
1
2
3 **
4 **
5 **
6 **
7 **
8 **
9 *
10 *
Bosch Sicherheitsysteme GmbH
Address
1560 – 1561
1562 – 1563
1564 – 1565
1566 – 1567
1568 – 1569
1570 – 1571
1572 – 1573
1574 – 1575
Exit Delay
Default
Address
0785 – 0787
45
0794 – 0796
45
0803 – 0805
45
0812 – 0814
45
0821 – 0823
45
0830 – 0832
45
0839 – 0841
45
0848 – 0850
45
0857 – 0859
45
0866 – 0868
45
Installation Guide
Default
Keypad
no.
01
9
99
10
99
11
99
12
99
13
99
14
99
15
99
16
Entry Delay
Default
Address
0788 – 0790 30
0797 – 0799 30
0806 – 0808 30
0815 – 0817 30
0824 – 0826 30
0833 – 0835 30
0842 – 0844 30
0851 – 0853 30
0860 – 0862 30
0869 – 0871 30
Address Programming | en
Address
Default
1576 – 1577
99
1578 – 1579
99
1580 – 1581
99
1582 – 1583
99
1584 – 1585
99
1586 – 1587
99
1588 – 1589
99
1590 – 1591
99
Entry Delay
Default
2 Address
0791 – 0793 30
0800 – 0802 30
0809 – 0811 30
0818 – 0820 30
0827 – 0829 30
0836 – 0838 30
0845 – 0847 30
0854 – 0856 30
0863 – 0865 30
0872 – 0874 30
2014.11 | 02 | F.01U.267.112
127