05 – Delay 1 Exit
The delay 1 exit zone type performs as described below:
1.
2.
3.
06 – Interior Delay 1 Exit
The Interior delay 1 exit zone type performs as described below:
1.
2.
3.
07 - Delay 2
The delay 2 zone type performs as described below:
1.
2.
3.
08 – Interior Delay 2
The interior delay 2 zone type performs as described below:
2014.11 | 02 | F.01U.267.112
AWAY Arm: same as the delay zone AWAY arm status
STAY Arm:
This zone will be ignored and performed as disarm.
Refer to Keypad Indicators to see how the zone is displayed during exit time.
DISARM: same as instant zone disarm status
AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - entry time starts - no alarm / no report
Disarming during entry time - no alarm / no report
Zone triggered - during exit time - no alarm / no report / abbreviates remaining time
for exit to 5 seconds
Zone triggered - during entry time - no alarm / no report
Zone triggered - entry time is expired - alarm / report (report is delayed for 30
second, when system is disarmed before, no report)
STAY Arm: same as AWAY arm performance
First delay zone will start the entry time; all other delay zones will follow.
When system is disarmed and zone is not restored before, a zone restore report is
sent.
Disarm: same as the instant zone disarm status
AWAY Arm: same as the delay exit zone AWAY arm status
STAY Arm:
This zone will be ignored and performed as disarm.
Refer to Keypad Indicators to see how the zone is displayed during exit time.
Disarm: same as instant zone disarm status
AWAY Arm:
Zone normal - no alarm / no report
Zone triggered - entry time starts - no alarm / no report
Disarming during entry time - no alarm / no report
Zone triggered - during exit time - no alarm / no report
Zone triggered - during entry time - no alarm / no report
Zone triggered - entry time is expired - alarm / report
(report is delayed for a specified time (default: 30s; value range: 00-99), when
system is disarmed before, no report)
STAY Arm: same as AWAY arm performance.
First delay zone will start the entry time; all other delay zones will follow.
When system is disarmed and zone is not restored before, a zone restore report is
sent