en | Optional Modules and Peripheral Devices
5.8

RF Radion Receiver

5.8.1

General

The RADION receiver OP is a wireless receiver that connects the RADION wireless system
components to the AMAX panel 3000/4000. Features include the following:
Installation
1.
2.
5.8.2

Address Setting

Set the rotary switch to 1. The AMAX panel supports only one receiver.
5.8.3

Wiring

1.
2.
5.8.4

Status Indicator

The following table describes the system status indicator of the RFRC-OPT Radion receiver.
On
Stable flash
Turns off momentarily
3 quick flashes
Off
Table 5.13: RFRC-OPT Radion Receiver System Status Indicator
2014.11 | 02 | F.01U.267.112
Cover and wall tamper protection
RFID and configuration data contained in persistent memory
Detection and reporting of radio frequency interference
Support of two types of device enrollment
Disconnect all power supplies of the AMAX panel before installing B450.
Mount the receiver onto a wall in a location accessible for future maintenance using the
provided anchors and screws. For best reception, place the receiver in a central location
among the transmitters. In situations where there is a large distance between the
transmitter and receiver, it might be necessary to install receivers for optimum results.
Connect the RADION receiver to the option bus.
Make sure that the cable distance to the AMAX panel doesn't exceed 300 meters.
LED Condition
Normal operation
Receiver is being programmed with the zone and transmitter IDs
from the AMAX panel.
Receiver has obtained a valid transmission from a RADION
transmitter.
Communication error and/or self-test failure
Causes:
Power failure or wiring failure
A communication failure between the AMAX panel and the
receiver or
An invalid address switch setting