Status Indicator; Dx3010; General; Address Setting - Bosch AMAX 2100 Installation Manual

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

18
en | Optional Modules and Peripheral Devices
5.3.4

Status Indicator

LED Condition
On
Stable flash
Off
5.4

DX3010

5.4.1

General

The AMAX panel supports DX3010 output expansion modules. Each module supports 8 fully
programmable relay outputs.
For information on the installation, refer to Module Installation, page 25.
5.4.2

Address Setting

Each DX3010 module connected to the AMAX panel needs its own data bus address.
Data Bus Address
150
151*
Table 5.7: DX3010 Address Settings
DIP Switch
Data Bus Address
150
151*
Table 5.8: DX3010 DIP Switch Settings
* AMAX 3000 / 4000
Example : Data Bus Location 150 - DIP Settings
Figure 5.5: DX3010 DIP Switch Settings
2014.11 | 02 | F.01U.267.112
Denotation
Trouble Condition:
Grounding Conductor is not connected or there is a
communication failure between the module and the AMAX
panel
No zones distributed
Module address setting error
Normal Operation
Power failure
S1
S2
1
2
On
On
Off
On
On
Off
Installation Guide
Outputs
5-12
13-20
S3
S4
4
8
On
On
On
On
Bosch Sicherheitsysteme GmbH
AMAX 2100 / 3000 / 4000
S5
S6
16
Mode
On
Off
On
Off