Advertisement

AMAX 2100 / 3000 / 4000
Digit Required
0
1
2
3
4
5
6
7
Table 7.1: Dialing Digits
How to program an IP address and port:
1.
2.
3.
4.
Example
4
Notice!
Programming option anti-replay, acknowledge wait time, and pulse interval time are only used
in Conettix IP.
Telephone number for Receiver 1 - 4/IP Address and Port
When the corresponding data format for above programming address is a network
communication format, it is explained as an IP address, and port. For a non network format, it
is explained as a telephone number.
The AMAX panel contacts the telephone number / IP Address of the central monitoring station
in order to transmit a report. If the contact is successful, the relevant information is
transmitted, and the communicator returns to standby mode.
Contact your monitoring station for the correct telephone number / IP address before you
program these addresses.
Receiver Subscriber ID Number
Receiver 1 - 4 Subscriber ID Number
The subscriber ID number is transmitted to identify the calling AMAX panel. Only digits from 0
to 9. SIA DC09 supports letters from A to F.
1.
2.
Example
4
Bosch Sicherheitsysteme GmbH
Number to Program
0
1
2
3
4
5
6
7
Use no punctuation in the IP address.
If any unit of the IP address has less than 3 digits, use 0 to fulfill the data in the higher
bits.
The remaining 5 digits program the port. Port number ranges from 0-65535.
If a port number has less than 5 digits, use 0 to fulfill the data.
To program the IP Address "10.16.1.222:80" as the IP address of receiver 1, enter the
following sequence into address 000 – 016:
[0 1 0 0 1 6 0 0 1 2 2 2 0 0 0 8 0]
Enter the subscriber ID number in the six addresses provided for each destination.
If a subscriber ID number has less than 6 digits, use 0 to full fill the data in the higher
bits.
Program subscriber ID number as 4729 in six addresses: [0 0 4 7 2 9]
Digit Required
8
9
*
#
4 sec pause
Terminal
Installation Guide
Settings | en
33
Number to Program
8
9
11
12
13
15
2014.11 | 02 | F.01U.267.112