en | Settings
26 – Instant Report
The instant report zone type performs as described below:
1.
2.
3.
Zone in Area
Each zone is assigned to an area. This assignment influences the way how zones are indicated
on keypads. For more information, please refer to Zone Indication Keypad and Event Log, page
64.
RF Zones
The AMAX panel 3000 / 4000 identifies RF zones by Zone RFID. AMAX Keypad programming
supports entering RFID automatically for Radion devices. When zone RFID is asked, press *
button for 3 second toggles between AUTO and MANUAL mode. When MANUAL is selected,
enter 9 – digit RFID using pin keys. When AUTO is selected, trigger RF device in order to enter
RFID automatically.
Hardwired Input Zones
On-board Inputs:
The AMAX panel provides onboard hard-wired inputs. An additional input is provided for the
enclosure tamper.
On-board Zone Response Time:
The AMAX panel supports different response times for the onboard zones. The response time
value range is 000.0-999.9 seconds.
On-board Zone EOL
Single EOL: If the zone tamper function is not selected, each zone uses a single 2.2 kilo ohm
EOL. The panel can detect the zone as short, normal or open.
Loop Resistance (ohm)
Min
0
1650
2970
The detectors (sensors) will be connected between zone and COM terminal through EOL
series (open triggered) or parallel connection (short triggered).
2014.11 | 02 | F.01U.267.112
Disarm:
Zone normal – no action
Zone triggered – report
AWAY Arm: same as disarm performance
STAY Arm: same as disarm performance
Type
2200
COM
Zone
Max
1430
2750
Installation Guide
AMAX 2100 / 3000 / 4000
Zone Status
triggered
normal
triggered
Bosch Sicherheitsysteme GmbH