AMAX 2100 / 3000 / 4000
On
Figure 5.1: 6-Position DIP Switch
DIP switches 5 and 6 are not used.
Address setting for IUI-AMAX-LED8 and IUI-AMAX-LCD8 Keypads
IUI-AMAX-LED8 and IUI-AMAX-LCD8 keypads can be set only to address 1 or address 2 through
the address jumper.
Address 1
Address 2
Table 5.3: Keypad Jumper Settings
5.2.3
Wiring
The following graphic shows how to wire a keypad to the option bus of the AMAX panel. The
last keypad must be placed within a cable distance of 200m.
AMAX 2100 / 3000
AMAX 4000
Figure 5.2: Connecting a keypad to the AMAX Panel
Notice!
The maximum number of keypads to be added to one option bus is 8.
5.2.4
Status Indicator
If all indicators of the keypad are flashing, the keypad loses connection to the AMAX panel.
Bosch Sicherheitsysteme GmbH
Off
Jumper not short-circuited
Jumper short-circuited (both metal pins are covered)
Optional Modules and Peripheral Devices | en
Keypad