AMAX 2100 / 3000 / 4000
Notice!
If the default pads are short-circuited for over 10 seconds after power-up, the AMAX panel
discards resetting to factory default.
7.6

Outputs and Sirens

7.6.1

Outputs

Onboard / Extension Output
The AMAX panel is equipped with on-board outputs and supports DX3010 output extension
modules with each extension module supporting 8 relay outputs.
When on-board output 1 or 2 fails due to a short circuit or an open circuit, as long as there is a
backup power supply, the output fault will not affect the normal operation of the whole
system, but will be detected by the system.
Each output is programmable and can be set to follow multiple events.
Depending on the type of the output event, the output parameters can be defined as area
output or follow zone alarm output. The output polarity of each output can be programmed
and defined as one of the following modes: continuous output, pulse output or inverted
output.
The maximum output time is specified by programming and will automatically be reset after
expiration.
Output Events - Overview
Output event
type
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Bosch Sicherheitsysteme GmbH
Description
Not Used
System Disarmed
System Armed
System Alarm
System Alarm (audible and silent)
External AWAY Siren
External STAY Siren
Internal Siren
Internal Siren with Tamper
Entry / Exit delay Warning
Telephone Line Fault
AC Power Supply Fault
Low Battery
Tamper
External Fault
Installation Guide
Settings | en
Output area / zone
No
0 = All areas
1 – 16 = areas 1 – 16*
0 = Any area
1 – 16 = areas 1 – 16*
1 – 16 = areas 1 – 16*
0 = Any area
1 – 16 = areas 1 – 16*