en | Settings
Receiver Network Programming Options
When the AMAX panel transmits a report via a network, the following options should be
programmed other than the IP address and port.
Anti Reply
Anti replay prevents unauthorized messages from being sent to the Central Monitoring Station
and being recognized as originating from the AMAX panel.
4
Acknowledge Wait Time
When no callback from the receiver after the acknowledge time is reached, the AMAX panel
takes it as an unsuccessful communication and makes another attempt. The time ranges from
5 to 99 sec.
4
Network Polling Time
The polling is used for both panel and remote receiver to know whether the network
connection is good or not. Each time when polling is due, the AMAX panel will send a polling
message. The polling time ranges from 1 to 999 minutes.
1.
2.
7.1.2

Reports

System Reporting
Report Transmission Sequence
If the event has disabled the report (option 0), no report is sent out. If the report has any
destination to contact the panel (option 1, 2, 3, 4, 5, 6, 7), It will call the related destination
by related reporting format type and subscriber ID Number.
Attempt rules:
1.
2.
3.
4.
Sequential Logic to Send Report
2014.11 | 02 | F.01U.267.112
Contact your central monitoring station for the correct setting.
Contact your central monitoring station for the correct setting.
For time less than 3 digits, use 0 to fulfill.
Contact your central monitoring station for the correct setting.
Attempt times and duration
Within the report expiring time the AMAX panel will retry sending the report to each
enabled destination till the report has been sent to the destination, or till the report
buffer overflows and the old report is replaced by new incoming reports.
For each enabled destination, the retry interval time between two retries is 15
seconds for the 1st retry to 4th retry, and the retry interval time between two retries
is 10 minutes for the 5th retry to 8th retry, after the 8th retry the retry interval time
between two retries is 60 minutes.
Attempt Priority
The attempt priority is destination 1, 2, 3, 4 Domestic. The disabled destinations will
be ignored.
Communication Fail Fault
If the attempt times for one destination reaches 4, the system will cause the
communication fail fault for this destination.
Backup Destination Process
The AMAX panel can save up to a maximum of 50 un-reported events. If the un-
reported events are more than 50, it will delete earlier event and only save the last
50 events in the buffer to send out.
If the event reporting path is set to 0, the relevant reports will not be sent
Installation Guide