AMAX 2100 / 3000 / 4000
Zone Status Reporting
The AMAX panel reports the zone status according to the specified path, including alarm, zone
fault, zone bypass and zone tamper alarm.
Zone Chime Mode
The system will support the chime mode.
The process is as follows:
Zone Pulse Count
The system will support the pulse count mode.
The process is as follows:
The process is as follows:
Domestic no.
The system will support the domestic call mode.
The process is as follows:
Cross Zone
The cross zone option works as follows:
Prerequisites:
When one of these zones is triggered for more than 20 seconds, an alarm is created.
When one of these zones (the first zone) is triggered for a shorter time than 20 seconds, the
cross zone timer starts, no alarm is created at this time
Unverified Alarm Report
Enables / disables the option unverified alarm report. When a cross zone is triggered, but no
alarm is created, system creates an unverified alarm in order to report. System reports
unverified alarms if option unverified alarm report is enabled.
Bosch Sicherheitsysteme GmbH
If the chime mode is used and a zone is triggered the keypad buzzer will sound for 1
second (only in disarmed status).
Pulse count duration time must be configured (refer to Pulse Count Duration Programming,
page 126)
Pulse count for a zone can be set to a value between 1 and 9 (0 = disabled)
An alarm is created only if the zone is triggered as many times as the value "pulse count"
within the time "count duration"
If the domestic call mode is configured for a zone and an alarm from this zone is created
the alarm will be reported to the destination(s) configured and needs acknowledgement
At least two zones in the same area have option cross zone enabled
System option cross zone timer is set to a value higher than 0
When no more zones (with cross zone option) are triggered within the cross zone time,
no alarm is created
When the first zone is triggered twice or more within the cross zone time, no alarm is
created
When a second zone or further zones (with cross zone option) is / are triggered within
the cross zone time, then an alarm is created for all triggered zones
When the first zone or one of the other zones (with cross zone option) is / are triggered
twice or more after cross zone time is expired, the timer restarts