en | Settings
Remote IP Access
This option enables/disables the remote IP access. If this option is enabled and a connection
is initiated via the PC software A-Link Plus, the system does not verify the IP address, but
verifies the subscriber ID and the installer code. RPC can not link to the panel via IP.
Force Arm When System Is In Trouble Condition
This option enables/disables the forced arming of an area although it is in a fault or tamper
condition.
Event Record Count per Set/Unset Period
This option defines the maximum number of records for an event within the set / unset period.
Language Version
In this option, the currently used language can be changed to the displayed languages.
Keypad 2 Button Alarm
This option enables/disables the keypad 2 button function:
The emergency alarm is transmitted, if [1] and [3], or [*] and [#] are pressed and held for
three seconds. The fire alarm is transmitted, if [4] and [6] are pressed and held for three
seconds. The silent keypad emergency alarm is transmitted, if [7] and [9] are pressed and
held for three seconds.
System Tamper Indication
System Tamper All Areas
This option defines where the system tamper event is indicated. System tamper indication can
be assigned to either the area where zone 1 is located in or to all areas.
Zone Tamper Bypass when DEOL Zone is Bypassed
If the option is enabled, the system creates a tamper alarm when DEOL zone is tampered,
even when this zone is bypassed.
Enclosure Tamper Timing
The AMAX panel supports different response times for the onboard tamper used for panel
enclosure. The response time value range is 000.0-999.9 seconds.
Area Name
This option is used to name areas. Therefore, the numbers on the text keypad function as an
alphabetical input:
Number on the
text keypad
1
2
3
4
5
6
7
2014.11 | 02 | F.01U.267.112
Alphabetical input when number is pressed consecutively
. , ' ? ! " 1 - ( ) @ / : _ ¹ ² ³ © ® º « » µ ¶
a b c 2 æ å ä à á â ã ç ć č
d e f 3 è é ê ë ð ę
g h i 4 ì í î ï ğ
j k l 5 £
m n o 6 ö ø ò ó ô õ ñ
p q r s 7 ß š ś ş
Installation Guide
AMAX 2100 / 3000 / 4000
Bosch Sicherheitsysteme GmbH