48
en | Settings
Exit Programming Mode
without saving
Exit Programming Mode with
saving
Set Factory Default
Copy Control Panel Data to
Programming Key
Copy Programming Key Data
to Control Panel
Display Firmware Version
* This function can be enabled/disabled.
+ This function can be enabled/disabled individually for every user.
D = Duress User
A = Arming User
B = Basic User
S = Super User
M1 = Master User 1
M2 = Master User 2
IN = Installer
Notice!
The installer commands can be used only when all areas of the system are in disarming status
with no alarm activated and when the installer access is enabled by the user.
7.2.3
Code Length
The length of the codes can be set in a range from 4 to 6 digits.
7.2.4
Code Reporting
The following codes are reported when an alarm occurs:
Installer
User 1 - 250
A-Link
Phone arm
Single-Button arm / disarm
Key switch arm / disarm
7.2.5
Code Permissions
Tamper Reset by User
This option defines whether tampers can be reset with a user code. If this option is disabled,
tamper resets can only be performed with the installer code.
2014.11 | 02 | F.01U.267.112
[9] [5] [9] + [#]
[9] [6] [0] + [#]
[9] [6] [1] + [#]
[9] [6] [2] + [#]
[9] [6] [3] + [#]
[9] [9] [9] + [#]
Report = 0
Report = 1 - 250
Report = 251
Report = 252
Report = 253
Report = 254
Installation Guide
AMAX 2100 / 3000 / 4000
√
√
√
√
√
√
Bosch Sicherheitsysteme GmbH