Macro Configuration; Zones; Add / Delete Zone - Bosch AMAX 2100 Installation Manual

Hide thumbs Also See for AMAX 2100:
Table of Contents

Advertisement

AMAX 2100 / 3000 / 4000
Arm / Disarm Installer
This option defines whether the arm / disarm function can be performed with a installer code.
If this option is disabled, the arm / disarm function can not be performed with an installer
code.
7.2.6

Macro Configuration

Macros are used to assign complicated or often used operation to one button to simplify the
operation of the system. It is possible to record up to three macros.
Input Macro Number
In this option the number of the macro to be configured is selected. (Possible numbers are 1,
2 and 3.)
Macro without Code
This option enables/disables the quick play function of the macro. If this function is enabled,
the user can press the number of the macro for three seconds to execute the macro playing
function without entering a code.
Macro Recording Timeout
This option defines the timeout of the macro recording process. (Possible values are 01 – 99
seconds.) The timeout defines the time after which the macro recording process is cancelled
due to inactivity of the user.
Play Pause Time
This option defines the speed of the macro playing process. If a user wants to observe the
macro playing process more closely, it can be adjusted to display the single operations longer.
The default setting is 03=300ms and can be adjusted to 01=100ms, 02=200ms and so on.
Code inside Macro Enable
This option enables/disables the code inside a macro. This function is relevant only if the
macro without code function is disabled.
If this function is enabled, a code will be recorded during the macro recording process and
will be executed during the macro playing process. This means that a user switch is possible
when the macro playing function is executed.
If this function is disabled, there will be no code recorded during the macro recording process
and the operation assigned to the macro will be executed without a code. This means that
there is no user switch possible in the macro playing function and that the user who is
executing the macro playing function is also executing the operation assigned to the macro.
7.3

Zones

7.3.1

Add / Delete Zone

When adding or changing a zone, it is required to select the area, the zone functions and the
module of the zone source, based on zone numbers.
When the zone is specified as "0", i.e. the zone is not used; any address set on the zone
function and module selection is invalid.
Zone Module
The AMAX panel supports onboard zones, keypad zones, AMAX 3000 / 4000, and DX2010
zones and RF zones.
Zone Function / Type
Zone Function Option
Zone Type
Bosch Sicherheitsysteme GmbH
Description
00
Not used
Installation Guide
Settings | en
49
2014.11 | 02 | F.01U.267.112

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax 3000Amax 4000

Table of Contents