Address Programming

The control panel programming options are stored in a non-volatile flash memory. This
memory has all relevant configuration and user-specific data even after a total power loss.
Because the data retention time is quite long without power, reprogramming is not required
after powering up the control panel.
Programming with keypad is possible only when all of zones in the system are in disarmed
status and no alarm is activated. The installer code is required for programming.
Notice!
It is not recommended to use other keypads or methods simultaneously to program the
system while programming with the current keypad.
The following chapters show an overview of all relevant programming options and their
addresses according to the descriptions in the chapter Settings, page 32.
9.1

Communication and Report Programming

9.1.1

Receiver Programming

Receiver No.
1
Bosch Sicherheitsysteme GmbH
Option
Transmission format for receiver (0 = not
used, 1 = CID, 2= SIA, 3 = Conettix IP, 4 = SIA
DC 09, 5 = SIA DC09 (2x ID))
Telephone number / IP address and port
Subscriber ID number (0 – 9, B – F)
Anti-replay for receiver (0 = disabled, 1 =
enabled)
Acknowledge wait time for receiver (05 - 99
seconds )
Network polling time for receiver (001 - 999
minutes )
DC09 data format (1 = ADM-CID, 2 = SIA-
DCS)
DC09 acct1 length (3 – 16, all other input is
treated as "3")
DC09 acct1 (0 - 9 = 0 - 9, 10=A, 11=B, 12=C,
13=D, 14=E, 15=F)
DC09 acct2 length length (3 – 16, all other
input is treated as "3")
Installation Guide
Address Programming | en
Address
Default
0023
1
0000 – 0016
15
0017 – 0022
000000
0024
1
EN=1
0025 – 0026
05
0027 – 0029
001
0140
1
0141 – 0142
06
0143 – 0158
000001
000000
0000
0159 – 0160
06
2014.11 | 02 | F.01U.267.112