Download Print this page

Control Panel Programming - Bosch ICP-CP4TS Installation Manual

4.3”

Advertisement

4.
Active Zones
5.
Active Outputs
6.
Active Areas
7.
PIN Code Digits
8.
Contact Details
The next five options effect what buttons are made available for ARMING of the
system. If NO is selected then that button will not be made available to the user.
These options are - Away Arm - Stay Arm - Stay 2 Arm - All Areas Arm - All
Areas Disarm.
The next five options all ask whether a PIN code is required for various functions.
They are Code for Away - Code for Stay - Code for Stay Disarm - Code for
Isolate - Code for Day alarm.
The next four options relate to Duress/ Panic functions. They are Codepad Duress -
Medical Panic - Fire Panic - Police Panic. If any of the Panic functions are set
as NO then they will not be displayed on the Emergency screen.
The RF Fobs option when set as YES allows the user to add remote controls via the
Radio Keyfobs option in the Settings menu. This is used for WE800EV2. When
RF Devices is set to YES the installer is able to add Bosch Ultima wireless
equipment by selecting RF Devices from the Settings - Installation menu.
The next two options decide whether Output Control and Output Reset are available to
the user.
When Domestic Dialling is set as YES the user is able to view and alter the numbers
dialled by the alarm panel via the Settings - Dialling option.
The next two options in the menu decide whether Day Alarm is available to the user
and whether this can be reset via the Day Alarm Reset.
Call Forwarding option set to YES will redirect incoming calls to another number
when the system is armed in Away.
Erase All Settings will revert all programming back to the factory defaults.

Control Panel Programming

The control panel can be fully programmed from the Touch Classic. There are two
available programming modes. The first uses the familiar method as per a LED or
ICON codepad. The second mode is an enhanced version with added features.
=
Set which zones will be displayed
=
Select outputs that will be displayed
=
Select areas to be displayed ( partition)
=
Select from 4 to 7 digit codes ( both user
and installer codes must be same length)
=
Select to enter installer contact details