Recommended Action:
System will reboot. Ensure all line cards, CPU, fan, and backplane are seated well. Run
diagnostics on the system to ensure there are no problems with the Control Module
card. If problem persists, call Cabletron Technical Support to resolve the problem.
-SYS-F-BADSLOTCPU is in an invalid slot <number> - must be in slot <number>
Explanation:
This message appears when the Control Module (CPU) is in an invalid slot.
Recommended Action:
Move the Control Module (CPU) to the appropriate slot. System will reboot.
-SYS-F-BUSERR bus error due to '<error>', at virtual address 0x<hex_value>
Explanation:
This message appears when a system bus error has occured.
Recommended Action:
System will reboot. Ensure all line cards, CPU, fan, and backplane are seated well. Run
diagnostics on the system to ensure there are no system problems. If problem persists,
call Cabletron Technical Support to resolve the problem.
-SYS-F-IVSYSTEM unrecognized or invalid system '<number>'
Explanation:
This message appears when The system ID is invalid.
Recommended Action:
The backplane ID is not valid for this version of Control Module and Software. Please
contact Cabletron Technical Support to resolve the problem.