Table of Contents

Advertisement

Quick Links

SSR-600 Installation Guide
Title Page
WIDE AREA 1
WIDE AREA 2
ETHERNET 1
ETHERNET 2
10/100
10/100
SPD/100
SPD/100
XMT
PWR
XMT
LNK
RCV
RCV
CPU
STS
TELCO
TELCO
RESET
CONSOLE
9033032-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSR-600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cabletron Systems SSR-600

  • Page 1 SSR-600 Installation Guide Title Page WIDE AREA 1 WIDE AREA 2 ETHERNET 1 ETHERNET 2 10/100 10/100 SPD/100 SPD/100 TELCO TELCO RESET CONSOLE 9033032-01...
  • Page 3 NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
  • Page 4 This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. SSR-600 Installation Guide...
  • Page 5 If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes. SSR-600 Installation Guide...
  • Page 6 BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU. SSR-600 Installation Guide...
  • Page 7 BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems Sales and Service, Inc. (“Cabletron”) that sets forth your rights and obligations with respect to the Cabletron software program (“Program”) in the package.
  • Page 8 BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU. SSR-600 Installation Guide...
  • Page 9 If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes. SSR-600 Installation Guide...
  • Page 10 BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, OR IN THE DURATION OR LIMITATION OF IMPLIED WARRANTIES IN SOME INSTANCES, THE ABOVE LIMITATION AND EXCLUSIONS MAY NOT APPLY TO YOU. viii SSR-600 Installation Guide...
  • Page 11 Legal Representative in Europe Mr. Ronald Fotino Mr. J. Solari ___________________________________ ___________________________________ Full Name Full Name Compliance Engineering Manager Managing Director - E.M.E.A. ___________________________________ ___________________________________ Title Title Rochester, NH, USA Newbury, Berkshire, England ___________________________________ ___________________________________ Location Location SSR-600 Installation Guide...
  • Page 12 Notice SSR-600 Installation Guide...
  • Page 13: Table Of Contents

    INSTALLATION Guidelines for Installation ............3-1 Unpacking the SSR-600 .............. 3-2 Installing Options ................. 3-2 3.3.1 Removing the SSR-600 Cover ........3-2 3.3.2 Optional SSR-600-ECM Installation ....... 3-4 3.3.3 Installing Sliding WAN Physical Interface Modules ..3-5 SSR-600 Installation Guide...
  • Page 14 Contents Installing the SSR-600 ..............3-6 3.4.1 Tabletop and Shelf Installations ........3-6 3.4.2 SSR-600 Rackmount Installation ........3-6 3.4.2.1 Tools Required..........3-7 3.4.2.2 Materials Required..........3-7 3.4.2.3 Attaching the Rackmount Brackets....3-8 Connecting to the Power Source ..........3-10 Connecting to the Network............3-11 3.6.1 Connecting to the Fast Ethernet Ports ......3-11 3.6.2...
  • Page 15: Figures

    Tabletop or Shelf Installation............ 3-6 SSR-600 Rackmount Hardware ..........3-7 Aligning the Brackets for Installation ........3-8 Installing the Rackmount Brackets ........... 3-8 Installing the SSR-600 in a 19-Inch Rack......... 3-9 3-10 Connecting a Twisted Pair Segment ........3-11 3-11 Crossover Cable RJ45 Pinouts ..........
  • Page 16 TABLES SSR-600 Hardware LED States ..........4-2 SSR-600 LAN LED States............4-3 Console Port LEDs..............4-3 Four Position Switch Bank Functions ........4-4 Console Port Connector Pinout..........A-2 Fast Ethernet RJ45 Pinout ............A-2 SSR-600 Installation Guide...
  • Page 17: Introduction

    Introduction provides preliminary information that will aid in using this manual, lists technology and user’s guides that may help the user to set up and manage the SSR-600, and provides instructions on how to get help from Cabletron Systems. Chapter...
  • Page 18: Ssr-600 Features

    OPTIONAL FEATURES Optional features for the SSR-600 include: • Rack mounting: The SSR-600 can be installed in a 19-inch rack with the optional mounting bracket kit (Cabletron part number SSR-600-RCK-KIT). Refer to Chapter 3, Installation, for rack mounting instructions.
  • Page 19: Related Manuals

    The manuals referenced above can be obtained on the World Wide Web in Adobe Acrobat Portable Document Format (PDF) at the following site: http://www.cabletron.com/ Cabletron Systems applicable software manuals for the SSR-600 and the HSIM-SSR-600 host platforms (Cabletron Routing Software Manuals): Bridging Configuration Guide...
  • Page 20: Document Conventions

    Tip symbol. Conveys helpful hints concerning procedures or actions. Caution symbol. Contains information essential to avoid damage to the equipment. CAUTION Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard. xviii SSR-600 Installation Guide...
  • Page 21: Getting Help

    A description of any action(s) already taken to resolve the problem (e.g., changing mode switches, rebooting the unit, etc.) • The serial and revision numbers of all involved Cabletron Systems products in the network • A description of your network environment (layout, cable type, etc.) •...
  • Page 22 Introduction SSR-600 Installation Guide...
  • Page 23: Chapter 1 Overview Of The Ssr-600

    This section details the hardware capabilities of the SSR-600. 1.1.1 WAN Connection The WAN connections to the SSR-600 are provided by the optional SWPIMs. The SSR-600 supports certain WAN protocols depending on the SWPIM installed. Refer to the appropriate SWPIM manual for detailed information on the SWPIMs chosen for installation.
  • Page 24: Ethernet Lan Connection

    • The SWPIM-BRI provides an Integrated Services Digital Network (ISDN) 64 or 128 Kbps Basic Rate Interface (BRI) for the SSR-600, and supports both the S/T-interface and the U-interface. The SWPIM-BRI can be used for Dial-up access. The SWPIM-BRI can also provide an ISDN back-up link for a remote site or branch office...
  • Page 25: Lanview Leds

    The RESET button is also used with the mode switches to clear NVRAM. 1.1.6 Console Port The console port of the SSR-600 is used to access software management by a direct connection to the SSR-600. Command Line Interface (CLI) is used to communicate with the SSR-600. Refer to Appendix A for the pinouts of the console cable.
  • Page 26: Optional Features

    This optional hardware data compression/encryption module accelerates data compression for the SSR-600 over Nailed-up PPP, or ISDN and Frame Relay with PPP riding underneath them. Depending on the packet type and size, hardware data compression provides data compression for enhanced throughput on each T-1 SWPIM interface.
  • Page 27: Chapter 2 Network Requirements

    World Wide Web site: http://www.cabletron.com/ 10BASE-T NETWORK When connecting a 10BASE-T segment to either of the SSR-600 ports, ensure that the network meets the Ethernet network requirements of the IEEE 802.3 standard for 10BASE-T. Refer to the Cabletron Systems Cabling Guide for details.
  • Page 28: 100Base-Tx Network

    Chapter 2: Network Requirements 100BASE-TX NETWORK The two fixed front panel ports of the SSR-600 provide an RJ45 connection that supports Category 5 UTP cabling. The device at the other end of the twisted pair segment must meet IEEE 802.3u 100BASE-TX Fast Ethernet network requirements for the devices to operate at 100 Mbps.
  • Page 29: Chapter 3 Installation

    CHAPTER 3 INSTALLATION This chapter outlines the procedure for setting up the SSR-600 and attaching it to the network. Ensure that the network meets the guidelines and requirements outlined in Chapter 2 before installing the SSR-600. Sections of this installation procedure may require the following items: •...
  • Page 30: Unpacking The Ssr-600

    If you have purchased the SSR-600-ECM auxiliary card, it must be installed before proceeding. The cover of the SSR-600 must be removed to install this option. The SSR-600 cover does not need to be removed to install the SWPIMs. The Cabletron Systems Sliding WAN Physical Interface Modules (SWPIMs) can be installed before or after the SSR-600-ECM installation.
  • Page 31: Removing The Chassis Cover

    Installing Options To remove the chassis cover, proceed as follows: Disconnect the SSR-600 from the network as follows (if applicable): Unplug the power cord(s) from the rear of the SSR-600 chassis. Before performing step b, mark any cables connected to the SSR-600 according to their associated port numbers.
  • Page 32: Optional Ssr-600-Ecm Installation

    CAUTION SSR-600. Figure 3-2 details the board layout of the SSR-600 to show where the SSR-600-ECM can be installed. To install an SSR-600-ECM to enhance the performance of your SSR-600, refer to the instructions enclosed with the SSR-600-ECM.
  • Page 33: Installing Sliding Wan Physical Interface Modules

    Figure 3-3 WAN SWPIM Ports Refer to the applicable SWPIM Installation Guide for information on how to safely install an SWPIM in the SSR-600 to enhance the capabilities of your SSR-600. After installing your SWPIM, refer to the applicable software guide for information on how to configure the SWPIM to connect it to the WAN.
  • Page 34: Installing The Ssr-600

    Chapter 3: Installation INSTALLING THE SSR-600 The SSR-600 may be installed on a tabletop, shelf or in a 19-inch rack. Refer to Section 3.4.1 for information concerning a tabletop or shelf installation. Section 3.4.2 describes the rackmount installation. 3.4.1 Tabletop and Shelf Installations...
  • Page 35: Tools Required

    Tools Required • Phillips screwdriver • Flat blade screwdriver 3.4.2.2 Materials Required The following parts are included in the SSR-600 rackmount kit (see Figure 3-6): • rackmount brackets (2) • 6-32 x 1/4 inch flathead screws (4) Do not use screws other than those supplied with the SSR-600 to perform the following procedures.
  • Page 36: Attaching The Rackmount Brackets

    Locate the two rackmount brackets. With the faceplate, or front of the SSR-600, towards you, align the front of the bracket with the front of the SSR-600. Locate the slots that align with the rear flanges of the bracket. See Figure 3-7.
  • Page 37: Installing The Ssr-600 In A 19-Inch Rack

    The SSR-600 may be mounted with the back of the unit facing out of the rack. In this position, the screws will be attached along the bottom edge of the SSR-600 (the SSR-600 must be right-side up). Otherwise, all other instructions apply, substituting the back of the SSR-600 for the front in the instructions.
  • Page 38: Connecting To The Power Source

    200–240 Vac, at 50 or 60 Hz. The voltage is automatically sensed when the power cord is plugged in. To connect the SSR-600 to the power source, perform the following steps: Plug the power cord into the back panel of the SSR-600.
  • Page 39: Connecting To The Network

    Chapter 3.6.1 Connecting to the Fast Ethernet Ports The two fixed front panel ports of the SSR-600 are 10/100 Fast Ethernet ports with internal crossovers. When connecting a workstation to the SSR-600, use a straight-through cable. When connecting other networking devices, such as a bridge, repeater, or router to the SSR-600, use a crossover cable.
  • Page 40: Crossover Cable Rj45 Pinouts

    (computer). A straight-through cable is used between hub devices. SSR600 Ethernet Port Other Device Port RX+ 1 NOTE: RX+/RX- and TX+/TX- must share a common color pair. RJ45 to RJ45 Figure 3-11 Crossover Cable RJ45 Pinouts 3-12 SSR-600 Installation Guide...
  • Page 41: Connecting Swpims To The Wan

    Guide. Refer to the Introduction for information on obtaining this document. If a link can not be established, contact Cabletron Systems. Refer to Getting Help, in the Introduction, for details. Repeat steps 1 through 3 above, for both connections, as needed.
  • Page 42 Chapter 3: Installation 3-14 SSR-600 Installation Guide...
  • Page 43: Ssr-600 Front Panel Leds

    4-1, Table 4-2, and Table 4-3 describe LED states. Table 4-4 describes switch positions. If you are having difficulty installing and configuring the SSR-600, perform the following steps: • Review Chapter 3 (Installation). • Verify that power has been applied to the SSR-600.
  • Page 44: Chapter 4 Troubleshooting, Switches, And Led Indications

    Chapter 4: Troubleshooting, Switches, and LED Indications FRONT PANEL LED INDICATIONS Table 4-1 SSR-600 Hardware LED States Color State None of the installed power supplies are operating, and the battery backup board is not operating (or not installed). All installed power supplies are SOLID GREEN operational.
  • Page 45: Ssr-600 Lan Led States

    Status (STS) SOLID GREEN Modem attached, carrier detected. BLINKING Port in test mode. YELLOW SOLID YELLOW Console attached. Table 4-3 SSR-600 LAN LED States Color State Speed is 10 Mbps. Fast Ethernet Speed (SPD/100) SOLID GREEN Speed is 100 Mbps.
  • Page 46: Switches

    The four-position switch bank has the functions shown in Table 4-4. The SSR-600 must be reset or powered down for the firmware to recognize the settings of the switches, and then implement any changes. Table 4-4 Four Position Switch Bank Functions...
  • Page 47: Switch Function Procedure

    Switches 4.2.1 Switch Function Procedure These steps must be followed to use the switch function: Remove power to the SSR-600. Remove the cover of the SSR-600. Refer to Section 3.3.1. Refer to Table 4-4 for a description of the switch functions.
  • Page 48: Troubleshooting Ssr-600 Hardware

    Receive (RCV) LED is OFF • Check that the SSR-600 and the device at the other end of the segment are powered up. • Check that the port is enabled. Refer to the appropriate Cabletron Systems software manual to enable the port.
  • Page 49: Appendix Aspecifications

    APPENDIX A SPECIFICATIONS This section describes the environmental specifications and safety and approval requirements for the SSR-600. Cabletron Systems reserves the right to change these specifications at any time without notice. PHYSICAL PROPERTIES 4.45 H x 43.18 W x 39.37 D (cm) Dimensions: 1.75 H x 17.0 W x 15.5 D (in)
  • Page 50: Console Port

    Appendix A: Specifications A.1.1 Console Port The RJ45 labled “console” on the front panel of the SSR-600 is used to access the Command Line Interface (CLI). Refer to the appropriate software manual for details. See Related Manuals in the Introduction.
  • Page 51 A and VCCI V-3 EN 50082-1 including: IEC 801-2 (ESD), IEC 801-3 (Radiated Susceptibility), and IEC 801-4 (EFT/B) NEBS (Bellcore) TR-NWT-000063: Network Equipment Building System (NEBS) Generic Equipment Requirements. GR-1089-CORE: EMC and Electrical Safety Generic Criteria for Network Telecommunications Equipment. SSR-600 Installation Guide...
  • Page 52 Appendix A: Specifications SSR-600 Installation Guide...
  • Page 53 RJ45 Pinout Flash EEPROMs Software Configuration 3-13 Getting Help SSR-600-ECM installation Guidelines for Installation Switch Bank Switches Help related manuals xvii Thermal Switch Troubleshooting Installation power connecting to the Network 3-11 SSR600 Hardware Installing Options SSR600 SSR-600 Installation Guide Index-1...
  • Page 54 Index Unpacking the SSR600 WAN Connection WAN Network Requirements Index-2 SSR-600 Installation Guide...

Table of Contents