-SYS-F-BADMEMSIZE memory sizing failed - size 0x<hex_value> is larger than
max. size of 0x<hex_value>
Explanation:
Control Module may have a hardware problem.
Recommended Action:
Configure the system to run diagnostics, then reboot. Note the diagnostics messages.
If any NIA failures are detected, the Control Modules may be bad and needs replacing.
-SYS-F-BADMEMWRITE memory write at location 0x<hex_value> failed,
wrote 0x%lx, read 0x<hex_value>
Explanation:
Control Module may have a hardware problem.
Recommended Action:
Configure the system to run diagnostics, then reboot. Note the diagnostics messages.
If any NIA failures are detected, the Control Modules may be bad and needs replacing.
-SYS-F-BAD_NIA_MEM Bad Memory at 0x<hex_value> on NIA
Explanation:
Control Module may have a hardware problem.
Recommended Action:
Configure the system to run diagnostics, then reboot. Note the diagnostics messages.
If any NIA failures are detected, the Control Modules may be bad and needs replacing.