Recommended Action:
Configure the system to run diagnostics, then reboot. Note the diagnostics messages.
If any NIA failures are detected, the Control Modules may be bad and needs replacing.
-SYS-E-PORTBUSWRITE Port bus write error at address 0x<hex_value>
Explanation:
Control Module may have a hardware problem.
Recommended Action:
Configure the system to run diagnostics, then reboot. Note the diagnostics messages.
If any NIA failures are detected, the Control Modules may be bad and needs replacing.
-SYS-E-XBARTMOUT Transmit timeouts to Xbar (destCEPs=0x<hex_value>)
Explanation:
Control Module may have a hardware problem.
Recommended Action:
Configure the system to run diagnostics, then reboot. Note the diagnostics messages.
If any NIA failures are detected, the Control Modules may be bad and needs replacing.
Fatal Messages
-SYS-F-2MANYCPUS too many CPUs, detected %d, architectural limit <num-
ber>
Explanation:
More than the architectural number of redundant Control Modules were detected.
Recommended Action:
Remove all extra Control Modules.
29 - 8
Chapter 29: SYS Error Messages
SSR-8 Error Reference Manual
Need help?
Do you have a question about the SmartSwitch Router and is the answer not in the manual?
Questions and answers