Automatic Route Steering Alarms - Furuno FEA-2107 Operator's Manual

Electronic chart display and information system (ecdis)
Hide thumbs Also See for FEA-2107:
Table of Contents

Advertisement

28. Trackpilot
28.5.7

Automatic route steering alarms

There are two types of alarms relevant to route steering, permanent and intermittent.
Permanent alarms are available regardless of the steering mode
used:
Outside channel is indicated by displaying the text "Off
track" in orange and its value in red.
The text "Out of Gate" is orange. Out of gate indicates that,
if the ship continues using the current course, the ship will be
outside of the channel at wheel over point.
Intermittent audio/visual alarms appear as follows:
Alarm number and text are visible at lower right corner of the ECDIS display (see example below).
The ACKN. WARNING button of the Trackpilot control panel lights to provide visual alarm (see example
below).
Buzzer sounds from the Trackpilot's panel.
You acknowledge an intermittent alarm by pressing the ACKN. WARNING button on the Trackpilot's panel.
FURUNO
28-16
FAP2000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fea-2107-bbFea-2807

Table of Contents