Alarms; Audio Alarm Type - Furuno RD-30 Operator's Manual

Multi display
Hide thumbs Also See for RD-30:
Table of Contents

Advertisement

1.7

Alarms

The RD-30 has ten conditions which can trigger audio and visual alarms: speed,
water temperature, depth, arrival/anchor watch, cross-track error, trip distance
(two alarms), countdown timer, alarm clock, no position fixing and no position
data.
Note: You can not turn off the no position fixing alarm nor the no position data
alarm.
1.7.1

Audio alarm type

Audio and visual alarms are released whenever an alarm setting is violated. You
can select the audio alarm type as follows:
1. Press the [MENU] key once or twice to show the main menu.
2. Select ALARM1 and then press the [ENT] key.
3. Press the [ENT] key to open the buzzer options window.
4. Use the cursor pad to select alarm type desired and then press the [ENT]
key.
SHORT:
LONG:
CONTIN.:
5. Press the [MENU] key twice to close the menu.
ALARM1
BUZZ :
LONG
SPEED: OFF
TEMP : OFF
DEPTH: OFF
ALARM1 menu
SHORT
LONG
CONTIN.
Buzzer options window
Two short beeps
Three long beeps
Continuous beep
30.0KT
+32.00 F
0.0FT
1. OPERATION
1-15

Hide quick links:

Advertisement

Table of Contents
loading