30. Alarms
Alarm number 6106:
------------------------------------
INDICATION WHILE LAN CONNECTION FOR
ARPA FEATURES IS ESTABLISHED BETWEEN
ECDIS PROCESSOR AND ARPA PROCESSOR
Alarm number 6107:
------------------------------------
FAILURE TO ESTABLISH LAN CONNECTION
FOR ARPA FEATURES BETWEEN ECDIS
PROCESSOR AND ARPA PROCESSOR.
CHECK LAN CONNECTORS AND CABLES
POWER ON/OFF AND REINSTALL ECDIS SW.
Alarm number 6108:
------------------------------------
FAILURE INSIDE ECDIS PROCESSOR
BETWEEN DLL INTERFACE SW AND ECDIS
SOFTWARE. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
Alarm number 6110:
------------------------------------
INDICATION WHILE LAN CONNECTION FOR
RADAR ECHO DATA IS ESTABLISHED
BETWEEN ECDIS PROCESSOR AND ARPA
PROCESSOR
Alarm number 6111:
------------------------------------
FAILURE TO RECEIVE RADAR ECHO DATA
FROM ARPA PROCESSOR OVER LAN
CONNECTION CHECK LAN CONNECTORS AND
CABLES. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
30-38
LAN RADAR CONNECT STATE 5/12
LAN RADAR CONNECT FAILURE 5/12
LAN RADAR DLL FAILURE
RADOV CONNECT STATE
RADOV NO ECHODATA