Furuno FEA-2107 Operator's Manual page 544

Electronic chart display and information system (ecdis)
Hide thumbs Also See for FEA-2107:
Table of Contents

Advertisement

30. Alarms
Alarm number 6307:
------------------------------------
FAILURE TO ESTABLISH LAN CONNECTION
FOR ARPA FEATURES BETWEEN ECDIS
PROCESSOR AND ARPA PROCESSOR.
CHECK LAN CONNECTORS AND CABLES
POWER ON/OFF AND REINSTALL ECDIS SW.
Alarm number 6308:
------------------------------------
FAILURE INSIDE ECDIS PROCESSOR
BETWEEN DLL INTERFACE SW AND ECDIS
SOFTWARE. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
Alarm number 6310:
------------------------------------
INDICATION WHILE LAN CONNECTION FOR
RADAR ECHO DATA IS ESTABLISHED
BETWEEN ECDIS PROCESSOR AND ARPA
PROCESSOR
Alarm number 6311:
------------------------------------
FAILURE TO RECEIVE RADAR ECHO DATA
FROM ARPA PROCESSOR OVER LAN
CONNECTION CHECK LAN CONNECTORS AND
CABLES. SWITCH POWER ON/OFF AND
REINSTALL ECDIS SW.
Alarm number 6400:
------------------------------------
NO HEADLINE AVAILABLE FOR RADAR
OVERLAY.
CABLING FOR RADAR OVERLAY
Alarm number 6401:
------------------------------------
NO AZIMUTH
OVERLAY.
CABLING FOR RADAR OVERLAY
30-42
LAN RADAR CONNECT FAILURE 5/12
LAN RADAR DLL FAILURE
RADOV CONNECT STATE
RADOV NO ECHODATA
RADOV NO HEADLINE
CHECK CONNECTORS AND
RADOV NO AZIMUTH
AVAILABLE FOR RADAR
CHECK CONNECTORS AND
5/12
6/13
7/14
6/13
6/13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fea-2107-bbFea-2807

Table of Contents