Other Features Of Vector Charts; Cell Status - Furuno FEA-2107 Operator's Manual

Electronic chart display and information system (ecdis)
Hide thumbs Also See for FEA-2107:
Table of Contents

Advertisement

8. Vector Chart Material
8.15

Other Features of Vector Charts

There are some functions or features which are not used on a daily or weekly basis, but sometimes there is a need to
use them.
8.15.1

Cell status

Use the Chart Cell Status function in the Chart Menu to find out the status of individual cells in your system, in a
CD ROM or in an RENC.
Status of CD ROM: This information is based on information in the CD ROM catalogue you have loaded and
chosen here from the CD ROM list box.
Status of RENC: This information is based on information in an RENC. One example of an RENC is PRIMAR.
You get the status of cells in an RENC via telecommunications, if you have optional telecommunication installed in
your system and you are a licensed user of an RENC.
Status of ENC: This information is based on information on the hard disk of the system. The ENC used here is
S57ed3 delivery formatted chart. Before it can be displayed as a chart it has to be converted into the system's
internal display format SENC.
Status of SENC: This information is based on information on the hard disk of the system. A SENC is the system's
internal display format.
Use the Conv Log button to view a detailed conversion log of S57 chart cell.
8-94