3.0 Facing and Finishing
3.1 Mantel Requirements
WARNING: All minimum clearances to combustible material MUST be maintained.
•
Combustible Mantel Projections: Mantel projections must fall within the 12" (305mm) combustible Wall Projection shown in
Figure 3.2. The combined wall projection, finishing material, and combustible mantel cannot exceed a 12" (305mm) projection.
•
Combustible Wall Bump-Out / Projection: You are allowed up to a 12" (305mm) wall projection starting at the top finishing
edge.
Note: At no point can any material extend to the inside of the glass viewing area. No material should block the viewing area or glass
of the appliance.
3.2 Hearth Requirements
•
Combustible Hearth Projections: Hearth projections are unlimited up to the bottom of the viewing area. See Figure 3.2.
Note: At no point can any material extend to the inside of the glass viewing area. No material should block the viewing area or glass
of the appliance.
Figure 3.1 - Installation Options with Mantels
Hussong Mfg. Co, Inc.
Osseo E-Series Electric Fireplace
18
Starting Serial Number: 23 OSE29000001 49,
Rev. 1 - January 2024
23 OSE34000001 49