Not Less than 36'' (91 cm) above any forced air inlet located within 10 feet (305 cm);
Not Less than 48'' (122 cm) below and horizontally from, or one foot (30 cm) above, any door,
window or gravity air inlet into any building;
Not Less than 24'' (61 cm) from an adjacent building and not less than 84'' (213 cm) above
grade when located adjacent to a public walkway.
Cannot be located less than 12 inches (300mm) above grade.
Cannot be located above a gas meter/regulator within 3 feet (900mm) horizontally of the
vertical center line of the regulator.
Not within 6 feet (1.8 meters) of a gas service regulator vent outlet.
Other restrictions may apply. See NFPA 211 for further information.

4.5 Installation Configurations

4.5.1 Installation Warnings, Cautions and Recommendations Reminder

PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED
THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR
JOINTS MUST BE SEALED AND FASTENED. CONSULT THE PELLET VENT
MANUFACTURER'S INSTRUCTION TO ENSURE PROPER INSTALLATION, CONSISTENT
PERFORMANCE, AND TO AVOID SMOKE AND ASH SPILLAGE.
USE RTV, METALLIC TAPE, AND A MINIMUM OF THREE SELF-TAPING SCREWS AT ALL
JOINT CONNECTIONS TO ENSURE A TIGHT SEAL.
THE CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF SPACE,
CLOSET OR SIMILAR CONCEALED SPACE OR FLOORS OR CEILING.
DO NOT INSTALL A FLUE DAMPER IN THE VENTING SYSTEM OF THIS STOVE.
INSTALL
VENTING
MANUFACTURER.
THE USE OF A SPARK ARRESTER AT THE END OF THE TERMINATION IS
MANDATORY.
Eurostar Installation and Operation Manual
SYSTEM
AT
CLEARANCES
SPECIFIED
BY
THE
VENT
17