BIO-45 MF FREESTANDING PELLET STOVE
Width: 27"
Height: 30 1/2"
Depth: 24 5"
Weight: 230 lbs.
Flue size: 3" or 4"
Hopper Capacity: Up to 60 lbs.
(This can vary widely depending on pellet size, length, and diameter)
EPA status: certified
Burn rate: 1.3 lbs to 5.5 lbs per hour
BTU range: 8,200 to 45,000
Electrical consumption: 3.5 Amps lighting cycle
2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
Igniter: 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional

PREPARATION

Factory packaging must be removed, and some minor assembly work is
required prior to installation:
The door overlay must be installed on the door frame;
The louver kit must be installed in front of the heat exchanger;
The black knob must be attached to heat exchanger rod;
The black coil handle must be attached to the handle rod;
Filters may be inserted between finger guard and convection
blower (see "filters assembly" section).
NOTE: Normally, your dealer will perform these functions.

CLEARANCES

TO
COMBUSTIBLES
PROTECTOR
The BIO-45 MF has been tested and listed for installation in residential
and mobile home.(refer figure 1 & 2)
FLOOR PROTECTION: In the USA, the unit must be installed on a non-
combustible floor pad extending at least 6 inches (155 mm) in front of
the door opening and at least 6 inches (155 mm) on each side of the
door opening. In Canada, the unit must be installed on a
noncombustible floor pad extending at least 18 inches (460 mm) in front
of the door opening and at least 8 inches (205 mm) at the back and on
each side of the unit. The floor pad must have a thickness of at least
0.015'' (0.38mm). NOTE: ceramic tile, or any tile, must be laid on a
continuous non combustible sheet to prevent the possibility of embers
falling through to the combustible floor if cracks or separation should
occur in the finished surface.
Clearances are measured from the sides, back and face (door opening)
or stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
This heating unit must serve as a supplementary heat source. An
alternative heat source should be available in the home if needed.
The manufacturer cannot be responsible for additional heating
costs associated with the use of an alternative heat source.
It is highly recommended that the user buys this product from a
retailer who can provide installation and maintenance advices.

INSTALLATION

AND
FLOOR
Corner installation
We recommend leaving 24'' on each sides of the appliance
in order to facilitate access for maintenance.
FIGURE 1
Back wall installation
FIGURE 2
Floor protection
CLEARANCES TO
COMBUSTIBLES
CANADA
A
2'' (55 mm)
B
6'' (155 mm)
C
2'' (55 mm)
D
3'' (80 mm)
FLOOR PROTECTION
CANADA
E
18'' (460 mm)
F
N/A (USA
only)
G
8'' (205 mm)
H
8'' (205 mm)
5
Ouverture
de porte
FIGURE 3
USA
2'' (55 mm)
6'' (155 mm)
2'' (55 mm)
3'' (80 mm)
USA
6'' (155 mm)
6'' (155 mm)
N/A (Canada
only)
N/A (Canada
only)