Installation Configurations; A) Horizontally Through Wall - Enerzone Euromax Owner's Manual

Hide thumbs Also See for Euromax:
Table of Contents

Advertisement

1.6.2. Installation Configurations

a) Horizontally through wall

(Refer to figures 11 or 12)
NOTE:
Follow
Vent
instructions.
1. Position stove, adhering to clearances shown in
Figures 1, 2, 3 & 4.
2. Locate position of hole in wall; directly behind
stove exhaust vent (refer to figure 5).
3. Always maintain 3" clearance from combustible
materials.
4. Install vent wall thimble per vent manufacturer's
instructions.
Attach enough piping to penetrate and extend at
least 6 inches beyond the exterior wall.
should always be at least one foot of vertical rise for
each foot of horizontal run (see Appendix A).
least 3 feet of vertical rise are needed in all cases. A
longer vertical rise will favour a better exhaust.
5. To reduce the risk of smoke spillage, never terminate with a horizontal run. If your system terminates with
a horizontal run, add at least 3 feet of vertical rise (see Appendix A).
6. Attach cap and seal outside wall thimbles with non-hardening waterproof mastic.
Termination should not be located so that hot exhaust gases can be a hazard to children. Exhaust gases can
reach temperatures of 500ºF and cause serious burns if touched.
Do not locate terminations:
In Canada:
a) less than 7 feet vertically above any public sidewalk, lane, street, right-of-way, stairway or
landing;
b) within 6 feet of a mechanical air supply inlet to a building;
c) within 3 feet of a building opening or air inlet of another appliance;
d) above a gas meter/regulator assembly within 3 feet horizontally of the vertical centerline of the
regulator
e) within 6 feet of any gas service regulator vent outlet or within 3 feet oa an oil tank vent or an oil
tank fill inlet;
f)
less than 1 feet above adjacent grade level or any adjacent surface that may support snow, ice,
or debris;
g) within 3 feet of the property boundary; and
h) underneath a veranda, porch, or deck.
i)
A clear space of at least 3 feet shall be provided from the termination to any building projection,
adjacent wall, or any combustible materials such as trees, shrubs, fencing, etc.
chimney
manufacturer's
There
At
FIGURE 11
Venting through wall