APPENDIX F: COMBUSTION AIR SUPPLY

WARNING: FOR MOBILE HOME INSTALLATION, IT IS MANDATORY TO CONNECT THE
STOVE TO AN OUTSIDE COMBUSTION AIR SOURCE. INSULATED PIPE SHOULD NEVER
EXCEED 10 FEET.
It is recommended to install an outside air inlet in or near the room where the stove is installed.
When doing so, it is preferable to choose a wall which is not exposed to dominant winds,
depending on the conditions surrounding your house.
AIR INLET
An insulated 3" inside diameter metallic pipe, either flexible or rigid, must be attached to the fresh
air intake (A).
A rodent guard (minimum ¼" wire mesh) must be used at the termination. All connections must be
secured and airtight by either using the appropriately sized hose clamp and/or UL-181-AP foil tape.
70
EXTERIOR WALL
INSULATED PIPE
AIR SUPPLY
A: FRESH AIR INTAKE
B: EXHAUST
Eurostar Installation and Operation Manual