 Power was interrupted while burning. After the cool down cycle, the stove will restart using
the last settings. Press "RESET" to go back to the Main Status Page.
Note: For a short power failure (less than 5 seconds), the stove will continue to function at the
selected speed.
SMOKE SMELL
 Venting system leaks. Inspect all vent connections. This is a pressurized venting system. All
vent connector joints must be sealed and fastened in accordance with the pellet vent
manufacturer's instructions to ensure consistent performance and avoid smoke and ash
spillage.
 Worn gasket. Gaskets may be leaking (Doors, clean out traps, etc). Make sure that all
gaskets are in good condition and replace them with original parts if necessary. Make sure the
door is well adjusted (see Section 8.1.9 Door Adjustment).
 Negative pressure. A faint wood-burning odor during ignition or shut down is normal.
Although, if this increases beyond normal or if you notice an unusual soot build-up on walls or
furniture, check your venting system carefully for leaks and make sure all gaskets are in good
condition. Also, make sure recommended maintenance schedule has been performed. Note
that you may need to add a fresh air kit to your stove to solve this problem. (see Appendix F :
Combustion Air supply)
COMBUSTION AIR STARVATION
 Venting system is dirty. Refer to the maintenance section of this manual.
 The flue is not properly installed. Make sure the venting system meets the criteria in the
installation section of this manual as well as the venting system manufacturer's instructions.
 Inadequate fuel is used. Remove the burn pot, make sure that all openings are clear and
check that no ash has filled the tube around the igniter. Refer to the maintenance section.
Also, make sure that recommended fuel is used (see Section 5.2.1 Proper Fuel) and settings
are adjusted to the type of pellets that are being used (see Section 6.1.6 Adjusting the
Combustion Level (Heat Output)).
 Air intake channel is restricted. Visually inspect the air intake channel that leads to the burn
pot for foreign material. Make sure that the air-intake shutter is functional and free of any
obstruction.
 The combustion/exhaust blower failed. Go to the troubleshooting page on the LCD screen
and test the combustion and the exhaust blowers independently (see Section 9.2 Testing
Components). If one of them does not work, make sure there is power and that blowers are
well connected. If they still don't work, check F4 and F5 fuse on the control board. If the fuses
are good, the combustion or exhaust blower is probably defective; Replace part.
THE LCD TOUCH SCREEN DOES NOT LIGHT.
 There is no current going to the stove. Check if the stove is connected and if there is
current in the wall outlet. Check if the F7 fuse is blown. Replace it if necessary.
 TELCO wire is defective of not connected properly. Convection blower, combustion
blower, exhaust blower and burn pot auger will start but the stove will beep continuously and
the LCD touch screen will remain black. Check connection and change wire, if necessary.
Eurostar Installation and Operation Manual