Enerzone EUROSTAR Installation And Operation Manual page 51

Table of Contents

Advertisement

THE AUGER FUSE BLEW UP
 The auger is jammed or auger motor failed. Go to the troubleshooting page (see Section
9.2 Testing components) on the LCD screen and test auger motors. If one of the motors is
not running check if motor is defective or jammed.
NOTE : IF THE HOPPER AUGER MOTOR FAILED OR THE HOPPER AUGER IS JAMMED, TO
AVOID PELLET SPILLAGE, EMPTY THE HOPPER OF ITS CONTENTS BEFORE EXECUTING
THE FOLLOWING TESTS.
o If the auger motor is defective, check to make sure that electrical connections are not loose
and check the fuses F2 and F6 on the control board. If the fuses are good, remove the
faulty auger motor from its auger housing and retest the motor separately still using the
troubleshooting test mode. Make sure the hopper lid is closed. If the motor works, the
auger may be jammed by a foreign object. If no signs of obstruction are found, call your
dealer or a service technician to perform a complete testing.
o If the hopper auger is jammed, start by emptying the hopper. If it is the burn pot auger you
don't need to empty the hopper. To remove both augers from their housing you need to
disconnect auger motor and then remove the four screws on the steel plate that holds the
auger shaft to the auger housing. You may need to remove the rear panel for an easier
access. Pull out the auger from the housing. Once the auger has been removed, make
sure there are no bent flights, burrs, or broken welds. Remove any foreign material that
may have caused the jam. Inspect the auger housing for signs of damage such as burrs,
rough spots, or grooves cut into the metal that could have caused a jam. Clean the auger
housing thoroughly to remove all pellet dust.
 The wiring harness shorted. Make sure the auger motor wiring is properly connected and
not shorted.
UNIT OVERHEAT
AN OVERHEAT ZONE WAS
DETECTED ON THE AUGER
HOUSING
RESET
DETAILS
 Inadequate fuel is used. Remove the burn pot, make sure that all openings are clear and
check that no ash has filled the tube around the igniter. Refer to the maintenance section.
Also, make sure that recommended fuel is used (see Section 5.2.1 Proper Fuel).
Eurostar Installation and Operation Manual
AUGER FUSE
RESET
DETAILS
THE FOLLOWING MAY HAVE CAUSED YOUR
PROBLEM (OVERHEAT):
• INADEQUATE FUEL IS USED
• THE FLUE IS NOT PROPERLY
INSTALLED
• THE FLUE IS BLOCKED OR
NEEDS CLEANING
• THE STOVE NEEDS
MAINTENANCE
THE FOLLOWING MAY HAVE CAUSED YOUR
PROBLEM (AUGER FUSE):
• THE AUGER IS JAMMED
• THE AUGER MOTOR IS DEFECTIVE
• THE WIRING HARNESS SHORTED
CONSULT OWNER'S MANUAL FOR
MORE DETAILS
BACK
BACK
THE FOLLOWING MAY HAVE CAUSED YOUR
PROBLEM (OVERHEAT):
• THE COMBUSTION CHAMBER IS
NOT AIR TIGHT
• THE CONVECTION BLOWER
FAILED
CONSULT OWNER'S MANUAL FOR
MORE DETAILS
BACK
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eurostar ep00055

Table of Contents