4.5.6 Through an Existing Masonery Chimney

1. Position stove following clearances shown
in Section 3.2 Minimum Clearances to
Combustibles
manufacturer's instructions.
2. Mark the center of the hole where the vent
pipe will go through the masonry chimney.
3. It is necessary to make a hole in the
masonry with a diameter of 4 " around the
mark for a 3'' pipe. For a 4'' pipe, a hole of
5'' in diameter.
4. Build
and
install
chimney. Stainless steel plate and screws
are recommended. Cut a hole for the vent
pipe. If needed, cut a second hole for the air
intake pipe. Seal all joints with high
temperature waterproof silicone sealant to
prevent water leakage.
5. Install the cleanout tee at the bottom of the
vertical vent system and lower it down the
chimney until the center branch of the tee is
aligned with the hole in the masonry.
6. Install
and
seal
temperature waterproof silicone sealant.
7. Seal and install vertical roof vent. If
required, seal and install a storm collar.
8. Connect the horizontal vent pipe to the
cleanout tee by pushing it through the hole
in the masonry.
9. If desired, once the horizontal pipe is in
place, the space between the pipe and
masonry
may
temperature grout.
10. If desired, install a trim collar and use an
additional horizontal vent pipe length, if
required, to connect the stove to the
chimney.
22
and
following
vent
flashing
above
the
flashing
with
high
be
filled
with
high-
Eurostar Installation and Operation Manual