United States:
· Not Less than 36'' (91 cm) above any forced air inlet located within 10 feet (305 cm);
· Not Less than 48'' (122 cm) below and horizontally from, or one foot (30 cm) above, any
door, window or gravity air inlet into any building;
· Not Less than 24'' (61 cm) from an adjacent building and not less than 84'' (213 cm)
above grade when located adjacent to a public walkway.
· Cannot be located less than 12 inches (300mm) above grade.
· Cannot be located above a gas meter/regulator within 3 feet (900mm) horizontally of the
vertical center line of the regulator.
· Not within 6 feet (1.8 m) of a gas service regulator vent outlet.
· Other restrictions may apply. See NFPA 211 for further information.
4.5 Installation Configurations
4.5.1 Installation Warnings, Cautions and Recommendations Reminder
· PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED
· THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR
JOINTS MUST BE SEALED AND FASTENED. CONSULT THE PELLET VENT
MANUFACTURER'S
CONSISTENT PERFORMANCE, AND TO AVOID SMOKE AND ASH SPILLAGE.
· USE RTV SILICONE (Room Temperature Vulcanisation), METALLIC TAPE, AND A
MINIMUM OF THREE SELF-TAPING SCREWS AT ALL JOINT CONNECTIONS TO
ENSURE A TIGHT SEAL.
· THE CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF
SPACE, CLOSET OR SIMILAR CONCEALED SPACE OR FLOORS OR CEILING.
· INSTALL VENTING SYSTEM AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
· THE USE OF A SPARK ARRESTER AT THE END OF THE TERMINATION IS
MANDATORY.