6.1.6.2 FUEL Q. ADJUST (Fuel Quality Adjustment)
The "FUEL QUALITY ADJUSTMENT" will allow you to modify default settings by +/- 5% for auger
motor 1 and +/- 10% for combustion and exhaust fan.
To restore default setting, select "DEFAULT".
Here are some situations where you may want to adjust these components:
Average speed of auger motor #1:
You may want to increase the auger motor #1 speed if fire goes out when combustion level is at
minimum setting. When burning poor quality pellets you may also need to reduce the auger motor
speed to avoid unburned pellets to fall into the ash drawer at any combustion level.
Speed of combustion fan:
You may want to reduce combustion fan speed if fire goes out when combustion level is at its
minimum setting. You may also want to increase combustion fan speed to avoid unburned pellets
to fall into the ash drawer at any combustion level.
Speed of exhaust fan:
You may want to reduce exhaust fan speed if natural draft is excessive and/or if the flame is low
and almost at the same height at any combustion level. You may also want to increase the exhaust
fan speed if vent configuration is too restrictive or flame height tends to be high at any combustion
level (see Appendix C: Flame Characteristics).

6.1.7 Convection Fan Speed Reduction (Optional)

When the grey fan icon
is displayed, the convection fan is on default setting. On default
setting the speed is synchronized with the auger feed rate. Selecting the grey fan icon will display
the "FAN SPEED CONTROL" screen. This will allow you to bypass the default settings. Sliding to
the left will reduce fan speed and sliding it to the right will increase fan speed. Note that you will be
able to decrease the fan speed to the lowest possible but not able to increase the fan speed higher
than the default fan speed for the current combustion level setting.
FAN SPEED CONTROL
SLIDE THE CURSOR TO SELECT THE FAN SPEED
BACK
OFF
SAVE & EXIT
Fan with red arrows icon will display
on the Main Status Page as you "SAVE & EXIT". Fan
speed reduction will be more noticeable on higher combustion level settings. To deactivate the fan
speed reduction, select "OFF" from this page.