Door Gasket Maintenance; Door Adjustment; Exhaust Channel And Exhaust Blower Maintenance - Enerzone EUROSTAR Installation And Operation Manual

Table of Contents

Advertisement

WARNING: IF YOU HAVE TO CHANGE THE DOOR GLASS, MAKE SURE YOU INSTALL THE
NEW GASKETS AT THE SAME PLACE AS THE ORIGINAL IN ORDER TO KEEP THE
AIRWASH WORKING PROPERLY.

8.1.8 Door Gasket Maintenance

It is important to maintain the door gasket in good condition. After a while, the gasket will wear and
compress; adjusting the door may then be required. If the door adjustment is not sufficient, replace
the door gasket with a genuine one. If the stove door is not properly sealed, it will be difficult to
keep the door glass clean and combustion gases may leak into the room.

8.1.9 Door Adjustment

In order for your stove to burn at its best efficiency, the door must provide a perfect seal with the
firebox. Therefore, the gasket should be inspected periodically making sure to obtain an air tight fit.
Airtightness can be improved with a simple latch mechanism adjustment. To adjust:
1. Remove the lock pin by pulling and turning
with pliers and turn the handle counter clock
wise one turn to increase pressure.

8.1.10 Exhaust Channel and Exhaust Blower Maintenance.

Exhaust channels and the exhaust blower are located on the left hand side of the stove. The
following procedure demonstrates how to perform inspection and cleaning:
In order to access the exhaust channels, open the left side decorative panels. Remove them if
necessary (Refer to decorative panel instruction sheet). Remove the two clean out trap. To remove
the clean out traps, you will need to unlock them first. Using a Philips or Robertson screwdriver,
push and turn the screw counter-clockwise and pull on the trap.
42
2. Re-install the lock pin (spring pin) with a
small hammer
Eurostar Installation and Operation Manual