Audio Alarm Verification
Connections (AAV, "Listen-In")
Refer to the connection diagram below.
Connections use one of the on-board triggers.
Suggested AAV Module:
ADEMCO UVS (shown) or Eagle 1250
UVCM
MODULE
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = ON
2 = OFF
3 = OFF
3 = OFF
4 = OFF
4 = ON
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
CONTROL
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
FALLING VOICE TRIG
GND
+12VDC IN
Figure 12. Connection of AAV Unit
Mounting and Wiring the Control
Notes
•
Set field *91 for AAV and program the
appropriate output (output 17 or 18) using
*80 Menu mode (select zone type "60").
•
For voice session monitoring, connect an
EOLR zone to UVCM module terminals 6
& 7, and program the zone as zone type 81
(*56 Menu mode).
E.g., Using output 18 for the trigger,
program an output function in *80 Menu
mode as:
ZT = 60, P = 0, Action = 1, Device = 18
TRIGGER
5
CONNECTOR
ZONE
TERMINALS
4
5
EOL
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
EARTH
GROUND
21
22
23
24 25
RING
TIP
RED (R)
GREEN (T)
RJ31X
GREY (R)
BROWN (T)
TO
PREMISES
HANDSET
INCOMING
PHONE LINE
2-19