Audio Alarm Verification Connections - Honeywell VISTA 15P - Ademco 6 Zone Control Panel Installation And Operation Manual

Ademco vista series
Hide thumbs Also See for VISTA 15P - Ademco 6 Zone Control Panel:
Table of Contents

Advertisement

Installation and Setup Guide
Audio Alarm Verification
Connections
(UVS System)
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
BANK 1
1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON
Figure 17a. Connection of AAV Unit When Not Using a 4286 Phone Module
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = OFF
2 = ON
3 = OFF
3 = OFF
4 = ON
4 = OFF
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
Figure 17b. Connection of AAV Unit When Using a 4286 Phone Module
2-14
Using the UVS System with UVCM Module
The UVS system provides audio alarm verification via the phone line.
• Refer to the connection diagrams below. One diagram shows connections when a 4286
Phone Module is used, the other shows connections when the 4286 is not used.
• Connections use one of the on-board triggers.
• Set field *91 for AAV and program the appropriate output (output 17 or 18) using *80
Menu mode: select zone type 60 and output action 1 (close for 2 seconds).
• For voice session monitoring, connect an EOLR zone to UVCM module terminals 6 & 7,
and program the zone as zone type 81 (*56 Menu mode).
E.g., Using output 18 for the trigger, program an output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
• Suggested AAV Module: ADEMCO UVS (shown) or Eagle 1250
U L
UL installations using the AAV feature must use the ADEMCO UVCM module (part of the
ADEMCO UVS system).
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
MODULE
SWITCH
BANK 2
1 = ON
2 = ON
3 = OFF
FALLING VOICE TRIG
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON
GND
+12VDC IN
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
RING
MODULE
TIP
FALLING VOICE TRIG
GND
+12VDC IN
TRIGGER
5
CONNECTOR
ZONE
CONTROL
TERMINALS
4
5
TRIGGER
5
CONNECTOR
ZONE
CONTROL
TERMINALS
4
5
4286
EARTH
GROUND
21
22
23
24 25
EOL
RING
TIP
RED (R)
GREEN (T)
RJ31X
GREY (R)
BROWN (T)
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
TO
PREMISES
HANDSET
INCOMING
PHONE LINE
21
22
23
24 25
EOL
RING
TIP
RED (R)
GREEN (T)
GREY (R)
OPTIONAL
BROWN (T)
MONITORING
ZONE
CONNECTION
(USE ZONE
TYPE 81)
TO
PREMISES
HANDSET
4
3
2
1
EARTH
GROUND
RJ31X
INCOMING
PHONE LINE