Honeywell ADEMCO VISTA-12A Installation And Setup Manual page 10

Hide thumbs Also See for ADEMCO VISTA-12A:
Table of Contents

Advertisement

Installation and Setup Guide
Keypad Addresses
Keypad
Address
no. 1
16**
no. 2
17
no. 3
18
no. 4
19
** The first keypad is address 16, which is always
enabled and set for partition 1 with all sounds on.
Wiring Run Chart For Devices* Drawing Aux Power From The Control (12V+ & 12V–)
TOTAL CURRENT DRAIN OF ALL DEVICES CONNECTED TO A SINGLE WIRE RUN
Wire Size
50mA or less
0.6mm O.D.
152m
0.8mm O.D.
228.6m
1mm O.D.
396m
1.2mm O.D.
457m
* Includes Keypads, RF Receivers, Zone Expander/Relay Units, or TeleCommand Phone Module.
Maximum wire lengths for any device that is wired directly to the control can also be determined from the Wiring Run
Chart, based on the current drain of that device alone.
The length of all wire runs for all partitions combined must not exceed 457m when unshielded quad conductor cable is
used (228m if shielded/screened cable is used). This restriction is due to the capacitive effect on the data lines when
quad cable is used.
2-4
Keypad Address
no. 5
20
no. 6
21
no. 7
22
no. 8
23
100mA
76m
116m
198m
305m
Keypads powered from supplies
that do not have a backup battery
will not function if AC mains
power is lost. Make sure to power
at least one keypad in each
partition from the control's
auxiliary power output.
300mA
500mA
24m
15m
40m
24m
67m
40m
100m
70m
600mA
13m
20m
35m
52m