Honeywell ADEMCO VISTA-12A Installation And Setup Manual page 54

Hide thumbs Also See for ADEMCO VISTA-12A:
Table of Contents

Advertisement

Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Display Options
*186
Entry 1: Latch first alarm in the display
0 = disable; 1 = enable
Entry 2: Blank the display (except for AC loss)
when not in exit delay, or 30 seconds
after disarm
0 = disable; 1 = enable
Sounder Mimic on Trigger 1
*187
0 = no sound output on trigger 1
1 = mimic keypad 1, address 16
2 = mimic keypad 2, address 17
3 = mimic keypad 3, address 18
4 = mimic keypad 4, address 19
5 = mimic keypad 5, address 20
6 = mimic keypad 6, address 21
7 = mimic keypad 7, address 22
8 = mimic keypad 8, address 23
Keypad Sabotage Options
*188
Entry 1: Keypad Lockout:
0 = disable; 1 = enable 15 minute lockout
Entry 2: Keypad Supervision and Tamper Fault
Detection: 0 = no, 1 = yes
4-18
EXPLANATION
Select the desired keypad display options.
Entry 1: If enabled, only the first zone that went into
alarm is displayed. Pressing the READY key will
scroll once through the other zones that went into
alarm, then the first zone in alarm will again be
displayed.
Enable this option if you want an external device
connected to trigger 1 to mimic keypad sounding.
NOTE: If using this option, trigger 1 must be
dedicated to only this function; do not assign any
other functions to trigger 1.
Entry 1. If selected, will lockout the keypad for 15
minutes if 30 keystroke entries (6 attempts of code +
command) are made without a valid user code being
detected. While the keypad is locked out, a message
"Code Sabotage" will be displayed on the keypads in
the partition that is locked out. A message will be
transmitted to the central station (461 Wrong Code
Entry) if Contact ID format is selected as reporting
format in field *48 (if Contact ID format is not being
used, this event is not reported). The Wrong Code
Entry is always logged in the event log.
Entry 2. Enables or disables keypad supervision
(ECP addresses 16-23) in the control. If selected,
keypads are supervised for connection and tamper.
These conditions cause a trouble when disarmed,
alarm when armed.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-12e

Table of Contents