Security Codes

The system supports up to 16 security codes, which can each be assigned one of 5 authority levels. The
authority level determines the functions each code can perform as follows:
Authority Levels (authority levels can be assigned to users 3-49 only; users 1 and 2 cannot be changed)
Level
User No.
Installer
01
System
02
Master
Partition
P1 = 03
Master
(default)
0-User
03-17
1-Arm Only
see "user"
2-Guest
see "user"
3-Duress
see "user"
4-Partition
see "user"
Master
Refer to the user guide for detailed procedures on adding/deleting security codes and changing user
attributes.
The following is a brief description of how to add user codes.
Adding a User Code:
Deleting a User Code:
Assigning Attributes:
6-6
Functions
perform all security functions except can disarm only if used to arm;
can enter program mode; can change System Master code; cannot
assign any other user codes (default = 4112)
only one system master code per system; can perform all security
functions, add/delete users in all partitions, change system master
code, view event log, set system clock, program keypad macro,
program scheduled events, activate output devices (triggers/relays)
(default = 1234)
Same as Master, except add/delete users limited to
assigned partition only, (these users can be assigned different
authority
levels, if desired; any user can be assigned the partition master
authority level)
perform security functions (arm, disarm, etc.) only; cannot add/delete
users, view event log, set system clock or program scheduled events
arm system only
can disarm the system only if it was used to arm the system
performs security functions, but also silently sends a duress message
to the central station; reports as duress code user number.
See Partition Master paragraph above; used to assign
other user numbers as partition masters
Master code + [8] + 2-digit user no. + user's code
Master code + [8] + 2-digit user no. + [#] [0]
Master code + [8] + 2-digit user no. + [#] [attribute no.] + value
Attributes:
1 = Authority Level
2 = Access Group
3 = Active Partition(s)
for this user;
4 = RF Zone No.
5 = Open/Close Paging
6 = Open/Close Report to 1 for yes (default = yes for all users), 0 for no
Monitoring Station
Values
0-4 (see Authority Level table above)
0-8 (0 = not assigned to a group)
1, 2, 3
Enter partitions consecutively if more than one
and press [#] to end the entries.
Assigns user number to button type zone for
arm/disarm (keyfob must be
enrolled in system first; see
Wireless Key Templates section)
1 for yes, 0 for no