FIELD
TITLE and DATA ENTRIES
Pager 1 Characters
*161
Enter up to 16 characters
Pager 1 Report Options
*162
0 = No reports sent
1 = Open/close for all users enabled to page†
4 = All alarms and troubles
5 = All alarms, troubles, and open/close for all
users enabled to page
12 = Alarms and troubles for zones entered in
zone list 9
13 = Alarms and troubles for zones listed in
zone list 9 and opens/closes for all users
enabled to page
Pager 2 Phone No.
*163
Enter up to 20 digits
4-14
EXPLANATION
Up to 16 optional characters may be sent as a prefix
to the 7-digit system status code sent to pager #1 (if
used). Phone number in field *160 must have been
entered. If fewer than 16 characters, exit by pressing
[∗] and next field number. To clear entries from this
field, press ∗161∗.
For example, use these optional 16 characters for the
following:
PIN number (to identify a specific pager to the
paging company)
Subscriber account number
∗ (enter # + 11 to send ∗); # (enter # + 12 to send #)
Pause (enter # + 13 to allow a 2-second pause)*
Any special character(s) the end user may decide
to transmit
* Some paging systems require pause(s) before the
prefix.
The format for the 7-digit system status code is
defined as follows:
Pager Format: XXX-YYYY where:
XXX
= 3-digit event code: 911 = Alarm
YYYY
= 4-digit user or zone number (depending
on type of event).
The first digit indicates partition,
followed by 0, then the 2-digit user or
zone number.
Example 1. Pager displays:
This indicates that the system is reporting an alarm
(911) caused by a fault in zone 4 in partition 1.
Example 2. Pager displays:
This indicates that the system is reporting a closing–
system arming (102) by User 5 in partition 2.
Enter the types of reports to be sent to pager 1 for
each partition.
† Reports to pager only when arming
(close)/disarming (open) from a keypad using a
security code; auto-arming/disarming, arming with
assigned RF button, and keyswitch arming do not
send pager messages.
If you enter fewer than 20 digits, exit by pressing [∗]
and next field number. To clear entries from this
field, press ∗163∗.
811 = Trouble
101 = Opening
(disarm)
102 = Closing (arm)
9 1 1 – 1 0 0 4
1 0 2 – 2 0 0 5