∗ ∗ ∗ ∗ 58 Expert Programming Mode Procedures
This method is designed for use by installers with previous experience in programming ADEMCO
control panels. This mode is also used to program wireless keys using pre-defined templates.
Start Expert Programming mode by pressing
prompts are displayed:
PROMPT
SET TO CONFIRM?
0 = NO 1 = YES 0
Zn ZT P RC HW: RT
01 09 1 10
EL
1
Zn ZT P RC IN: L
10
– :
5-6
58 while in Data Programming mode. The following
VALID ENTRIES
Confirm?
0 = no
1 = yes
[∗] to continue
Summary Screen
01-06, 9-24, 49-64 = zone
number
00 = quit
[∗] to continue
OR
[D] to go to prompts for wireless
key programming templates
EXPLANATION
If 1 (Yes) is entered, the XMIT TO CONFIRM
prompt appears later in this procedure after
entering RF transmitter serial and loop numbers,
and lets you confirm the programming of each RF
transmitter. We recommend that you confirm
every transmitter.
If 0 (No) is entered, the XMIT TO CONFIRM
prompt is automatically skipped.
This option is ignored if programming wired zones
only.
A summary screen will appear, showing zone 1's
currently programmed (or default) values.
Enter the zone number being programmed, then
press [∗], which displays a summary screen for
that zone. See next prompt (in this example, zone
10 is being entered).
If programming a wireless key, press the [D] key
then skip to the Wireless Key Programming
Templates section following this section. When [D]
is pressed, you can choose from a series of preset
templates for easy programming of wireless key
zones.
When all zones have been programmed, press "00"
at this prompt to quit this menu mode.